Crestron Isys i/O TPMC-15-CH Operation Manual page 26

Isys i/o tpmc-15/17 tilt series touchpanel media centers
Hide thumbs Also See for Isys i/O TPMC-15-CH:
Table of Contents

Advertisement

Touchpanel Media Centers
22
Touchpanel Media Centers: Crestron Isys i/O™ TPMC-15/17 Tilt Series
Crestron Isys i/O
CAUTION: Provide sufficient power to the system. Insufficient power can lead to
unpredictable results or damage to the equipment. Please use the Crestron Power
Calculator (www.crestron.com/calculators) to help calculate how much power is
needed for the system.
CAUTION: Possible equipment damage if miswired.
NOTE: When installing network wiring, refer to the latest revision of the wiring
diagram(s) appropriate to your specific system configuration, available from the
Crestron website.
NOTE: Do not power up system until all wiring is verified. Care should be taken to
ensure data (Y, Z) and ground (G) connections are not crossed when connecting the
TPMC-15 or TPMC-17.
When calculating the wire gauge for a particular Cresnet run, the length of the run
and the Cresnet power usage of each Cresnet unit to be connected must be taken into
consideration. If Cresnet units are to be daisy-chained on the run, the Cresnet power
usage of each network unit to be daisy-chained must be added together to determine
the Cresnet power usage of the entire chain. If the unit is a home-run from a Crestron
system power supply network port, the Cresnet power usage of that unit is the
Cresnet power usage of the entire run. The length of the run in feet and the Cresnet
power usage of the run should be used in the following resistance equation to
calculate the value on the right side of the equation.
Resistance Equation
40,000
R <
L x P
The required wire gauge should be chosen such that the resistance value is less than
the value calculated in the resistance equation. Refer to the table after this paragraph.
Wire Gauge Values
RESISTANCE
(R or Ohms)
4
6
10
15
13
8.7
NOTE: All network wiring must consist of two twisted pairs. One twisted pair is
the +24V conductor and the GND conductor. The other twisted pair is the Y and Z
conductors.
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
TPMC-15/17 Tilt Series
Where:
R = Resistance (refer to the following table).
L = Length of run (or chain) in feet.
P = Cresnet power usage of entire run (or chain).
WIRE GAUGE
2
(AWG)
(MM
)
16
1.50
18
0.75
20
0.50
22
0.34
Doubled CAT5
Tripled CAT5
Operations Guide - DOC. 6344