During wood combustion, the register of primary air must be opened only for a while, because otherwise
the wood burns too fast and the cooker may overheat.
Secondary air control ( extractable bar right Figure 1 )
Under the hearth door there is the right secondary air register. This valve must be opened (then totally
inserted) (see paragraph 10).
Smokes control (pull push lever)
(Conversion of the cooker function to the cooker, bake
oven and heating function Figure 1 – Figure 2).
The smokes control, in the style of a brass knob, can be
found on the top right corner of the front side of the
cooker, between the protection bar and the oven door.
This control has two settings:
HOB COOKING : when the bar is pushed to the back of
the cooker, the combustion gases flow around the oven
and directly into the flue and up to the chimney.
OVEN COOKING: when the control bar is pulled out,
the combustion gases flow around the oven, heating it.

3. INSTALLATION RULES

Installation of the thermo stove/cooker and auxiliary equipment in relation to the heating system must
comply with all current Standards and Regulations and to those envisioned by the law.
Installation relating to the connections of the system,
functioning must be carried out in compliance with the regulations in force by authorised professional
personnel with the requisites required by the law, being national, regional, provincial or town council
present in the country within which the appliance is installed, besides these present instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system
declaration of conformity certificate and will assume full responsibility for final installation and as a
consequence the correct functioning of the installed product.
NORDICA S.p.A. cannot be held responsible for lack of respect for such precautions.
Before installation, accurately wash the pipes of the system in order to remove any residuals that could
compromise the correct functioning of the appliance.
IMPORTANT:
a) In case of water leaking, close the water supply and promptly warn the after sales technical service;
b) The system working pressure must periodically be checked.
c) If not using the boiler for a long period of time, it is recommended that the after sales technical
service is contacted to carry out at least the following operations:
-
close the water taps of both the thermal system and the domestic hot water system;
-
empty the thermal system and the domestic hot water system if there is risk of freezing.
La Nordica S.p.a. declines all responsibility for damage to things and/or persons caused by the
system. In addition, it is not responsible for any product modified without authorisation and even
less for the use of non original spare parts.
Your local chimneysweep must be informed of the installation of the thermocooker, so that he can check its
correct connection to the flue and the level of efficiency of the flue itself.
NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE.
Before installation, check whether your floor can support the weight of the Thermocooker.
WARNING: ensure the device is placed perfectly level and that the diameter of the smoke exhaust
pipe is that required.
Connection of more that one cooker to the same chimney is not allowed.
It is advisable to have your local chimneysweep check both the connection to the chimney and the
sufficient flow of air for combustion in the place of installation.