LED
Description
Module Programming
Off
Module has no power.
Waiting to begin the programming sequence.
Solid red
Flashes green
CAN programmed and waiting for bypass programming. Normal operation.
quickly
Flashes orange
Waiting for offline Key2GO programming.
slowly
Solid green
Module successfully programmed or is already
x 3 secs then
flashes
programmed.
orange quickly
Solid green
Module successfully programmed
x 3 secs
Module Programming - Error Codes
Flashes red
CAN not detected.
x 2
Flashes red
Bypass data not detected.
x 3
External Module Synchronization
OBDII feature not supported.
(Flashes red,
red, then
orange) x 10
Active Ground When Running (Status)
Flashes
GWR (Status) command received.
green
Flashes
IGNITION ON command received.
red &
orange
Flashes
START ON command received.
green quickly
D2D & W2W Commands
Flashes
LOCK command received.
orange x 1
Flashes
UNLOCK command received.
orange x 2
Flashes
TRUNK command received.
orange x 3
RSR Code
3x OEM Lock Remote Start Activation was attempted
Flashes red
x 7
when RFTD feature is disabled.
Troubleshooting
Make sure the D2D harness is connected or that the 12
Volt is present between the red and black wires. If the
12 Volt is present, the module may be defective.
Ensure the correct programming procedure is being
followed.
Normal operation.
Normal operation.
Normal operation
Check the Tan - Tan/Black wire connections. Wake up
the data bus by turning the ignition on and try again.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the
ignition ON. Make sure the battery was removed when
turning the ignition ON.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by
missing wire connections or module hardware limitation.
Refer to "Installation" on page 8 to check the
connections.
Used to ensure the module has received the remote
start message and has enabled the remote start
runtime. Commands can come from RF or D2D.
Used to ensure the module received the ignition
command.
Used to ensure the module received the start command.
If the bypass module fails to flash, it means the module
did not receive the signal.
Activated from Web automatically when using RSR flash
tool or can be done manually. Refer to feature
programing section for more information.