Led Diagnostics & Troubleshooting - Directed Xpresskit DBALL2 Installation Manual

Range extender ready (rxt)
Hide thumbs Also See for Xpresskit DBALL2:
Table of Contents

Advertisement

Platform: DBALL2
Firmware:
CHRYSLER11 ange Extender
LED Diagnostics & Troubleshooting
LED
Description
Module Programming
Off
Module has no power.
Waiting to begin the programming sequence.
Solid red
Initialization failed.
Flashes red
& green
Transponder functions were skipped.
Solid orange
Flashes
All required CAN networks has been detected. Normal operation.
green
Flashes
1 of 2 CAN networks has been detected.
orange
Flashes
Key2GO initiated.
orange
slowly
Module was successfully programmed with all
Solid green
x 3 secs
functions.
Module was successfully programmed without
Solid orange
x 3 secs
transponder functions.
Module Programming - Error Codes
Flashes red
CAN2 not detected.
x 1
Flashes red
J1850 not detected.
x 1
Flashes red
CAN1 not detected.
x 2
Flashes red
Bypass data not detected.
x 3
Flashes red
Bypass processing error.
x 4
Flashes red
ISO 1 not detected.
x 5
Flashes red
ISO 2 not detected.
x 6
Flashes red
MUX not detected.
x 7
R
Ready
Troubleshooting
Make sure the D2D harness is connected or that the 12 Volt is
present between the red and black wires. If the 12 Volt is present,
the module may be defective.
Ensure the correct programming procedure is being followed.
Reset the module and complete the programming again. If the issue
persists, please contact Technical Support.
(If compatible) when RXT mode is not desired or convenience
features are needed, please reset and reprogram the module.
Normal operation
Please follow the steps indicated in "Module programming" to
complete the Key2GO programming.
Normal operation
Normal operation.
Check the CAN2 Orange/Green and Orange/Brown wire connections.
Wake up the data bus by turning the ignition on and try again. If your
installation does not require this connection, skip this step by
pressing the programming button 5 times.
Check the J1850 wire connection. Wake up the data bus by turning
the ignition on and try again.
Check the CAN1 Tan and Tan/Black wire connections. Wake up the
data bus by turning the ignition on and try again. If your installation
does not require this connection, skip this step by pressing the
programming button 5 times.
Check the bypass line connection. If more than one wire is used,
make sure they are not inverted. Ensure the vehicle still operates
correctly using the factory key.
The bypass calculation failed. Reset the module and try again. If the
condition persists, please contact Technical Support.
The Yellow/Black wire did not detect the expected signal. Refer to
"Installation (wiring diagrams & vehicle wiring reference charts)" to
check the connections.
The Orange/Black wire did not detect the expected signal. Refer to
"Installation (wiring diagrams & vehicle wiring reference charts)" to
check the connections.
The Violet/Green or Violet/Brown wire did not detect the expected
voltage value. Refer to "Installation (wiring diagrams & vehicle wiring
reference charts)" to check the connections.
Go to the next page to see the rest of the
(RXT)
Installation
LED
Diagnostics & Troubleshooting.
Rev.: 20170724
Page 11
© 2017 Directed. All rights reserved.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xpresskit chrysler11

Table of Contents