5.11
Automatic control parameter identification
With the function "Automatic control parameter identification"
•
mechanical distance parameters are identified by a short movement and
•
an automatic adjustment of the speed and position encoder based on the parameters is
identified or selected.
Stop!
•
An identification can only be carried out if the drive is not subject to external torque. In the
event of hanging loads (or similar) a motion cannot be activated through the function!
•
Release the brake (if mounted) before executing this function.
•
Ensure the following to keep the number of revolutions:
– Brake resistor or regenerative power supply
and
– constant moment of inertia.
•
If the values differ too much from the default setting of codes C1182 - C1185, deviations in
the identification of distance parameters and thus controller setting may occur.
•
The motion to be carried out by the function must be set in a way that even the slowest
rotating element of the controller train is still clearly moving.