Wan Port Set Up; Settings; Procedure - MCK EXTender 6000 Quick Installation Manual

Citel extender 6000: installation guide
Table of Contents

Advertisement

WAN Port Set up

The EXTender has two WAN ports (WAN 1 and WAN 2). The ports communicate via an RS-232,
RS-530 or V.35 interface and provide the connections to the third party network devices.

Settings

The following settings are available to the system administrator to manage
these WAN ports:

Procedure

1. Access the WAN 1 or WAN 2 Menu using the following path;
Path: Gateway->Configuration->WAN 1 or 2
The following menu appears.
2. Press the
key to access the Enabled parameter.
3. Press the
key to change the availability of the port to: Enabled (Yes ) or Enabled (No).
4. Press the
key to accept changes and go back to the Configuration Menu.
5. Press the
key to the Save parameter.
6. Press Enter to save changes to the active config (.rem) file.
EXTender 6000 Quick Installation Guide
Enabling/Disabling WAN ports- Individually Enable or Disable a specific
WAN port (below)
Setting the Sync Rate – Sets the specific WAN port to the sync rate (syn-
chronous serial port transfer speed) of the network device (CSU/DSU).
(refer to page 22)
Setting the Interface Mode- Choose the interface signaling type used to
communicate with the network device. (refer to page 23)
Figure 9:
WAN Menu
21