M10 ACCESS LEVEL
ALL USERS
Menu M10 sets the menu system access level.
Use + to change to "Authorised expert" and then Enter to set user level.
4.4.6 Menu S, Settings
The setting menus are used to change end user parameters for WATER TRACK U. To be able
to make changes to sub menus write access must be activated (changed to ON) before menu is
entered
S0 SETTINGS
WRITE ACCESS OFF
S1 AVERAGE LOW
TIME= 10 SECONDS
Time constant to control output filter when in low speed, i.e. speed is below
threshold set in menu S2.
Use – or + to change time constant and then Enter to save.
S2 THRES LOW-HI
THRESHOLD= 3.0 KN
Menu S2 sets the threshold when filter time constant shall be controlled by
menu S1 or S3.
Use – or + to change threshold and then Enter to save.
S3 AVERAGE HIGH
TIME= 10 SECONDS
Time constant to control output filter when in high speed, i.e. speed is above
threshold set in menu S2.
Use – or – to change time constant and then Enter to save.
S6 LOCK TIMEOUT
TIME= 20 SECONDS
Menu S6 controls maximum lock time, i.e. how long the latest speed value is
kept if new measured speed is invalid.
Use –+ or +– to change lock timeout and then Enter to save.