Service And Maintenance; Supervision And Diagnostic Codes - JRC JLN-900 Installation And Instruction Manual

Speed log
Table of Contents

Advertisement

8 Service and maintenance

Two red 7-segment LED digits on the Sig. Distributor PCB are used to display status. At
normal operation the LED digits displays LED code:
A service web interface is also available at the Sig. Distributor IP-address, see menu S18
and S19.

8.1 Supervision and diagnostic codes

The Sig. Distributor supervises functions according to the table below. Diagnostic codes 400 –
499 are reserved for the Sig. Distributor. Active diagnostics are presented in Menu A,
accessible both from the Speed Log Master Display and the Sig. Distributor Web interface. The
last hundred diagnostics are saved in a history list only accessible from the Web interface.
The LED code (the two last digits of the diagnostic code) will be displayed on the red 2 x LED
digits on the CPU-PCB. If more than one diagnostic is active, only the highest LED code
(highest priority) will be displayed. All active diagnostic codes are listed in Menu A.
Note! $SDALR messages from Echo Sounder Display are not supervised.
LED
Diagnostic
code *
code
00
(400)**
***
405
07
407
08
408
09
409
***
410
21
421
22
422
23
423
31
(431)**
32
(432)**
33
(433)**
34
(434)**
35
(435)**
36
(436)**
37
(437)**
38
(438)**
44
(440)**
4X
44X
5X
45X
6X
46X
Text
NORMAL OPERATION
SYSTEM MISMATCH
SOG LOG FAIL
STW LOG FAIL
SPEED LOG FAIL
ROT MISSING
SOG SERVICE REQ
STW SERVICE REQ
LOG SERVICE REQ
OVERFLOW OUT 1
OVERFLOW OUT 2
OVERFLOW OUT 3-6
OVERFLOW OUT 7
OVERFLOW OUT 8
OVERFLOW OUT 9
OVERFLOW OUT 10-15
OVERFLOW OUT 16-23
NMEA OVERFLOW
CORRUPT / BAUD IN X
POL / BAUD IN X
CHECKSUM ERR IN X
00
.
Description
NMEA input mismatch. Check System Type
(Menu S1)
Check SOG system. NMEA from SOG log 1
missing. Check IN1 / System Type
Check STW system. NMEA from STW log 1
missing. Check IN5 (always supervised)
Check LOG system. NMEA from speed log 2
missing. Check IN2 / System Type
NMEA from Gyro missing
(Docking: Menu S3 and S4 > 0)
Check SOG system
Check STW system
Check Sig. Distributor equipment. Check menu
system Diagnostics.
NMEA overflow on Out_1, terminal 36 (channel 0)
NMEA overflow on Out _2, terminal 37 (channel
1)
NMEA overflow on Out _3-6, terminal 38-41
(channel 2)
NMEA overflow on Out_7, terminal 42 (channel 3)
NMEA overflow on Out_8, terminal 43 (channel 4)
NMEA overflow on Out_9, terminal 44 (channel 5)
NMEA overflow on Out_10-15, terminal 45-46, 59-
62 (channel 6)
NMEA overflow on Out_16-23, terminal 63-70
(channel 7)
NMEA inputs overflow. Too high total serial data
load.
NMEA corrupt or wrong baud rate In_X (X = Input
1..9)
NMEA polarity or baudrate error In_X (X = Input
1..9)
Checksum error on NMEA In_X (X = Input 1..9)
6-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents