JRC JLN-900 Installation And Instruction Manual page 126

Speed log
Table of Contents

Advertisement

OPTO inputs:
I10 OPTO IN 1
ALARM MUTE
to
I13 OPTO IN 4
LOG 2 MAIN
The Sig. Distributor is equipped with four opto-isolated inputs that can be used to control the
system. Each input can be set according to the following list:
OPTO inputs
ALARM MUTE
ES 2 MAIN
LOG 2 MAIN
LOG 1 BT MUTE
LOG 2 BT MUTE
SD4 INVERT OFF
5.2.4 Menu M, Miscellaneous
When pressing the MENU button in the I0 INPUTS menu, M0 MISC is displayed.
M0 MISC
WRITE ACCESS OFF
Example of settings:
- Restore to default menu settings
- CPU Reboot
- Display SoftWare REVISION
- Display FirmWare REVISION
- Display HardWare REVISION
- ACCESS LEVEL
See table "Menu function summary" For a complete MENU list.
5.2.5 Menu N, NMEA out
When pressing the MENU button in the M0 MISC menu, N0 NMEA OUT is displayed.
NO NMEA OUT
WRITE ACCESS OFF
Setting concerning NMEA outputs are set under this menu.
For example:
- NMEA listeners
- Transmit baud rate
NMEA listeners:
N1 NMEA OUT1
ESD
to
Function
Mute an ESD Alarm
ES 2 (LOG 2) becomes the active Echo Sounder
LOG 2 becomes the active log
Mutes the BT / SOG transmitter of LOG 1
Mutes the BT / SOG transmitter of LOG 2
Deactivates the inverting function for an SD4 INVERTED
output channel. When active, the SD4 INVERTED nmea
output channels are identical to an SD4 nmea output.
Table 1 OPTO input list