READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
LZR-MICROSCAN T sensors are intended to be used with PEDESTRIAN, SWING-DOOR systems.
PRECAUTIONS
Shut off all power going to header before attempting any wiring procedures.
!
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by
CAUTION
the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any
board, ensure you dissipate your body's ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and
cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed
by BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
CLASS 1
LASER PRODUCT

GENERAL INSTALLATION TIPS

Avoid extreme vibrations.
Avoid moving objects, light sources, and highly reflective objects in detection zone.
Do not cover the sensor.
Always test the proper operation of the installation before leaving the premises.
The door control unit and the door header must be correctly grounded.
Only trained and qualified personnel are recommended to install and set up the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.

MAINTENANCE

- It is recommended to clean the optical parts at least once per year or more if required due to
environmental conditions.
- Do not use abrasive cleaning components.
75.5753.17 LZR-MICROSCAN T 20200109
75.5753.17 LZR-MICROSCAN T 20200109
IR laser (Class 1)
wavelength 905 nm
max. output pulse power 35 W
CAUTION: Use of controls or adjustments or
performance of procedures other than those specified
herein may result in hazardous radiation exposure.