Chroma 19071 User Manual page 77

Hipot tester
Hide thumbs Also See for 19071:
Table of Contents

Advertisement

Preset Parameters
Description:
It sets all parameters of Preset.
Command code: 0x25
Parameter:
6 bytes
Name
AC Frequency
Software AGC
WV Auto Range
IR Auto Range
GFI(Ground Fault Interrupt)
Fail Restart
Screen
Return data:
Reply Message
Example:
Master (0x70): 0xAB 0x01 0x70 0x08 0x25 0x32 0x00 0x01 0x00 0x01
0x01 0x00 0x2D
Slave (0x01): 0xAB 0x70 0x01 0x02 0x7F 0x00 0x0E
Descriptions of example
The setting meanings of HEX inputs are as the following:
0xAB = Header
0x01 = Destination Address
0x70 = Source Address
0x08 = Data Field Length
0x25 = Command Code
0x32 = ACV Frequency 50Hz
0x00 = Software AGC OFF
0x01 = WV Auto Range ON
0x00 = IR Auto Range OFF
0x01 = Ground Fault Interrupt (GFI) ON
0x01 = Fail Restart ON
0x00 = Screen OFF
0x2D = Checksum
The reading meanings of returning HEX code are as the following:
0xAB = Header
0x70 = Destination Address
0x01 = Source Address
0x02 = Data Field Length
0x7F = Reply Message Command Code
0x00 = Reply Message Return Data
0x0E = Checksum
Preset Parameter?
Description:
It queries all parameters of Preset.
Command code: 0xA5
Parameter:
None
Return data:
6 bytes
Example:
Master (0x70): 0xAB 0x01 0x70 0x01 0xA5 0xE9
Slave (0x01): 0xAB 0x70 0x01 0x08 0xA5 0x3C 0x01 0x00 0x01 0x01
RS485 Interface (For Link Model of 19073 + RS485)
Size (byte)
Unit
1
Hz
1
-
1
-
1
-
1
-
1
-
1
-
0x00 0x01 0xA2
Range
Description
50/60
0/1
0:OFF, 1:ON
0/1
0:OFF, 1:ON
0/1
0:OFF, 1:ON
0/1
0:OFF, 1:ON
0/1
0:OFF, 1:ON
0/1
0:OFF, 1:ON
5-11