Connect the Breakout Cable

Note: Unused bare wires can be clipped short or tied back using a tie made of non-conductive material.Keep all
bare wires separated from the +24VDC wire.
1. Verify that the 24VDC power supply being used is unplugged and not receiving power.
2. Optionally, connect the I/O or serial wires to an appropriate device (for example, a PLC, an encoder, or a serial
device). For more information, refer to
Note: When using an In-Sight 5604 line scan vision system, the RS-232RX wire is used as Encoder A and
the RS-232TX wire is used as Encoder B. For more information, refer to
on
page 18.
3. Attach the I/O Breakout cable's +24VDC (White/Green wire) and 24V COMMON (Brown wire) to the
corresponding terminals on the power supply. Refer to
details.
CAUTION:
Never connect voltages other than 24VDC. Always observe the polarity shown.
4. Attach the Breakout cable's M12 connector to the vision system's 24VDC connector.
5. Restore power to the 24VDC power supply and turn it on if necessary.
Breakout Cable Specifications on
Breakout Cable Specifications on page 22
Figure 2-3: Power Connections
page 22.
Encoder Inputs (In-Sight 5604 Only)
Installation