Cognex In-Sight 5000 Series Installation Manual page 28

Vision system
Hide thumbs Also See for In-Sight 5000 Series:
Table of Contents

Advertisement

Specification
Operating Temperature (non-circulating air)
Operating Temperature (circulating air)
Storage Temperature
Humidity
Protection
Shock
Vibration
Regulatory Compliance
1
The vision system should be mounted with sufficient clearance on all sides to allow air circulation around and through the cooling posts on the
black heat sink. If the vision system is not mounted with sufficient clearance, a fan is recommended.
2
Additional cooling from a fan is recommended for operation above 40°C. For operation up to 50°C, there must be ≥16 CFM of air moving
through the cooling posts on the black heat sink.
16
0°C to 45°C (32°F to 113°F)
0°C to 50°C (32°F to 122°F)
-30°C to 80°C (-22°F to 176°F)
95%, non-condensing (Operating and Storage)
IP67 (with appropriate lens cover properly installed).
80 G Shock with 150 gram lens attached per IEC 68-2-27.
10 G from 10-500 Hz with 150 gram lens per IEC 68-2-6.
CE, FCC, KCC, TÜV SÜD NRTL, RoHS
5604/5614
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents