Breakout Cable Specifications

The Breakout cable provides connection to an external power supply, RS-232 serial communications, acquisition trigger
input, high-speed outputs and encoder inputs (In-Sight 5604 only). The Breakout cable is not terminated. When using the
In-Sight 5604, refer to
Encoder Inputs (In-Sight 5604 Only) on
Table 3-9: Breakout Cable Pin-Out
Pin#
1
2
3
4
5
6
7
8
Note:
Cables are sold separately.
l
Unused bare wires can be clipped short or tied back using a tie made of non-conductive material. Keep all
l
bare wires separated from the +24VDC wire.
The housing of the vision system is internally connected to the system ground wire (pin 8 of the Breakout
l
cable). Therefore, if the mounting surface of the vision system is at a non-zero ground potential, it is strongly
recommended that the vision system be mounted on an isolated or non-conductive mount.
1
If hardware handshaking is required, an I/O module must be used.
2
If hardware handshaking is required, an I/O module must be used.
22
page 18.
Signal Name
+24VDC
TRIGGER+
TRIGGER-
HS OUT 0
HS OUT 1
1
RS-232 RECEIVE (RxD)
(In-Sight 5604 Only: Encoder A)
RS-232 TRANSMIT (TxD)
(In-Sight 5604 Only: Encoder B)
24V COMMON
White/Green
Green
White/Orange
Blue
White/Blue
Orange
2
White/Brown
Brown
Wire Color