Table Of Contents; Introduction - EAS Electric ETH-80VM Installation & Owner's Manual

Thermal monoblock
Table of Contents

Advertisement

CONTENTS
1
INTRODUCTION.....................................................................1
2
ACCESSORIES......................................................................2
3 SAFETY CONSIDERATIONS.................................................2
4
BEFORE INSTALLATION......................................................3
5
REFRIGERANT USED............................................................4
6 SELECTING INSTALLATION SITE........................................4
7 PRECAUTIONS ON INSTALLATION.....................................5
8 TYPICAL APPLICATION EXAMPLES...................................7
9 OVERVIEW OF THE UNIT.....................................................18
10 START-UP AND CONFIGURATION.....................................36
11 TEST RUN AND FINAL CHECK...........................................49
12 MAINTENANCE AND SERVICE...........................................49
13 TROUBLE SHOOTING.........................................................49
14 TECHNICAL SPECIFICATIONS...........................................55
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE
FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCKS, SHORT-CIRCUITS, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE TO
ONLY USE ACCESSORIES MADE BY THE SUPPLIER
WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH
THE EQUIPMENT AND HAVE INSTALLATION DONE BY A
PROFESSIONAL
ALL ACTIVITIES DESCRIBED IN THIS MANUAL SHALL BE
CARRIED OUT BY A LICENSED TECHNICIAN.
BE
SURE
TO
WEAR
PROTECTION SUCH AS GLOVES AND SAFETY GLASSES
WHEN PERFORMING INSTALLATION, MAINTENANCE
OR SERVICE TO THE UNIT.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
CONTACT YOUR DEALER FOR GUIDANCE
PAGE
OR
ATTACHMENT
OF
ADEQUATE
PERSONAL
1

1 INTRODUCTION

1.1 General information
■ These units are used for both heating and cooling applications.
They can be combined with fan coil units, floor heating
applications, low temperature high efficiency radiators, domestic
hot water tanks (field supply) and solar kits (field supply).
■ A wired user interface is supplied with the unit to control the
installation.
The unit is delivered with an integrated backup heater for
additional heating capacity during cold outdoor temperatures. The
backup heater also serves as a backup in case of malfunctioning
and for freeze protection of the outside water piping during winter
time. The capacity of backup heater for different units is listed below.
Capacity/Load
3
Tbivalent
1. Heat pump capacity
2. Required heating capacity (site dependent)
3. Additional heating capacity provided by backup heater
1-phase
Unit
5
9
7
Capacity of
3kW
backup heater
(optional)*
The backup heater is a split part, it is an option for the main unit.
If the backup heater is installed, the
control board of hydraulic should connect to the corresponding
port in the backup heater box
Function diagram of hydraulic compartment
■ Domestic hot water tank (field supply)
A domestic hot water tank can be connected to the unit(with or
without electrical booster heater is both OK).
There is a heat exchanger in the tank. If the heat exchanger
outside is enameled, the heat exchanger surface must be bigger
than 1.7m
for matching the 10kW ~16kW unit and the heat
2
exchanger surface needs to be bigger than 1.4m
5kW~9kW unit.
■ Room thermostat (field supply)
Room thermostat can be connected to the unit(room thermostat
should be kept away from heating source when selecting the
installation place).
■ Solar kit for domestic hot water tank (field supply)
An optional solar kit can be connected to the unit.
■ Remote alarm kit (field supply)
A remote alarm kit can be connect to the unit.
■ Operation range
HEATING MODE
T4
35
30
-2
-20
5 12
40
55
60
1
2
Outdoor temperature
3-phase
10
12
14
16 12
14 16
3kW(standard)
4.5kW
4.5kW(optional)
port (CN6) for T1 in the main
(more details please refer to
9.2.2
)
for matching the
2
COOLING MODE
T4
46
20
10
-5
T1
T1