EAS Electric ETH-80VM Installation & Owner's Manual page 170

Thermal monoblock
Table of Contents

Advertisement

Model(s):
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters
shall be declared for low-temperature application.
Parameters shall be declared for average, colder and warmer climate conditions
Item
Rated heat output (*)
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
Tj = bivalent temperature
Tj = operating limit
For air-to-water heat pumps:
Tj = -15℃
Bivalent temperature
Cycling interval capacity for
heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
off mode
standby mode
thermostat-off mode
crankcase heater mode
Other items
Capacity control
Sound power level, indoors/
outdoors
Annual energy consumption
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Annual electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters
YES
NO
NO
NO
YES
NO
Symbol
Value
Unit
Prated
15
kW
Pdh
8.8
kW
Pdh
5.3
kW
Pdh
3.4
kW
Pdh
2.5
kW
Pdh
10.6
kW
Pdh
6.4
kW
Pdh
9
kW
T
-11
°C
biv
P
-
kW
cy ch
C
0.9
--
dh
P
0.017
kW
of f
P
0.017
kW
sb
P
0.006
kW
to
P
0.018
kW
ck
variable
L
-/71
dB
WA
kWh
Q
14341
HE
or GJ
-
Q
-
kWh
elec
AEC
-
kWh
EAS ELECTRIC
Pol. Industrial San Carlos, Parcela 13 03370 Redován (Alicante)
www.easelectric.es
ETH-160VM
Item
Symbol
Seasonal space heating
ηs
energy efficiency
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
COPd
Tj = -7℃
COPd
Tj = 2℃
COPd
Tj = 7℃
COPd
Tj = 12℃
Tj = bivalent temperature
COPd
COPd
Tj = operating limit
For air-to-water heat pumps:
COPd
Tj = -15℃
For air-to-water heat pumps:
TOL
Operation limit temperature
COP
Cycling interval efficiency
PERcyc
Heating water operating limit
W
temperature
Supplementary heater
Rated heat output (**)
Psup
Type of energy input
For air-to-water heat pumps:
_
Rated air flow rate, outdoors
For water- or brine-to-water
heat pumps: Rated brine or
_
water flow rate, outdoor heat
exchanger
Water heating energy
η
wh
efficiency
Daily fuel consumption
Q
f uel
Annual fuel consumption
AFC
81
Value
99
2.20
3.20
4.52
6.41
1.86
1.16
1.64
-20
or
cy c
-
40
TOL
8.5
Electrical heating
6150
-
m
-
-
-
Unit
%
-
-
-
-
-
-
-
°C
%
°C
kW
m³/h
3
/h
%
kWh
GJ
V.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eth-110vmEth-125vmEth-140vmEth-160vm

Table of Contents