EAS Electric ETH-80VM Installation & Owner's Manual page 133

Thermal monoblock
Table of Contents

Advertisement

How to set the OTHER HEATING SOURCE
To set the OTHER HEATING SOURCE, go to MENU> FOR
SERVICEMAN> OTHER HEATING SOURCE, Press OK.
The following page will appear:
7 OTHER HEATING SOURCE
7.1.BACKUP HEATER
7.2.AHS
7.3.SOLAR ENERGY
SCROLL
If backup heater is available, please select YES at BACKUP
HEATER. Press OK and the following page is displayed:
7.1 BACKUP HEATER
HEAT MODE
DHW MODE
T4_IBH_ON
dT1_IBH_ON
t_IBH_DELAY
t_IBH12_DELAY
SCROLL
When the cursor is on HEAT MODE or DHW MODE, Use ◄ ► to
select YES or NON. If YES is selected, the backup heater will be
available in the corresponding mode, otherwise it will be unavailable.
When the cursor is on T4_IBH_ON、dT1_IBH_ON、t_IBH_DELAY、
or t_IBH12_DELAY, Use ◄ ► and ▼ ▲ to scroll and adjust the
parameter.
T4_IBH_ON is the ambient temperature for starting the backup
heater. If the ambient temperature rises above T4_IBH_ON, the
backup heater will be unavailable. The relationship between operation
of the backup heater and the ambient is shown in the picture below.
Heat mode
Heat mode by heat
by IBH only
pump and IBH
T4HMIN
dT1_IBH_ON is the temperature difference between T1S and T1 for
starting the backup heater. Only when at the T1<T1S-dT1_IBH_ON
can the backup heater turn on. When a second backup heater
is installed, if the temperature difference between T1S and T1 is
larger than dT1_IBH_ON+2, the second backup heater will turn on.
The relationship between operation of the backup heater and the
temperature difference is shown in the diagram below.
T1S-dT1_IBH_ON
IBH1 ON
T1S-dT1_IBH_ON-2
IBH2 ON
t_IBH_DELAY is the time that the compressor has run before the
first backup heater turns on (if T1<T1S).
t_IBH12_DELAY is the time that the first backup heater has run
before the second backup heater turns on.
YES
NON
YES
NON
YES
NON
YES
NON
YES
NON
-5 °C
5 °C
30MIN
5MIN
Heat mode
by heat pump
OFF
T4HMAX
T4_IBH_ON
IBH1 OFF
T1
IBH2 OFF
T1
T1s-T1
dT1_IBH_ON+2
dT1_IBH_ON
dT1_IBH_ON-2
IBH 2
OFF
OFF
IBH 1
ON
OFF
Compressor
t_IBH_delay t_IBH12_delay
If an additional heating source is available, please select YES at
the corresponding position. Press OK and the following page is
displayed:
7.2 ADDTIONAL HEATING SORUCE
HEAT MODE
DHW MODE
T4_AHS_ON
dT1_AHS_ON
dT1_AHS_OFF
t_AHS_DELAY
When the cursor is on HEAT MODE or DHW MODE, Use ◄► to
select YES or NON. If YES is selected, the additional heating source
will be available in the corresponding mode, otherwise it will be
unavailable.
NOTE: If YES is selected in DHW MODE, the installation of an
additional heating source should follow "8.5 Application 5/Applica-
-tion b"
When the cursor is on T4_AHS_ON、dT1_AHS_ON、dT1_AHS_
OFF or t_AHS_DELAY, Use ◄ ► and ▼ ▲ to scroll and adjust the
parameter.
T4_AHS_ON is the ambient temperature for starting the additional
heating source. When the ambient temperature rises above T4_AHS_
ON, the additional heating source will be unavailable. The relationship
between the operation of additional heating source and ambient
temperature is shown in the picture below:
Heat mode
Heat mode by heat
T4
by AHS only
pump and AHS
T4HMIN
dT1_AHS_ON is the temperature difference between T1S and T1B for
turning the additional heating source on(only when T1B<T1S-dT1_AHS
_ON will the unit turn on), dT1_AHS_OFF is the temperature difference
between T1S and T1B for turning the additional heating source off (
when T1B≥T1S+dT1_AHS_OFF the additional heating source will turn
off), t_AHS_DELAY is the time that the compressor has run before
starting the additional heating source. It should be shorter than the
additional heating source start time interval.The operation of the heat
pump and the additional heating source is shown below:
T1s-T1B
dT1_AHS_ON
dT1_AHS_OFF
OFF
AHS
ON
Compressor
OFF
t_AHS_delay
If solar energy kit is installed, please select YES at "7.3 SOLAR ENERGY",
then the solar pump will operate when the solar energy kit operating for
domestic hot water heating, and the heat pump will stop operating for
domestic hot water heating.
44
T4<T4_IBH_ON
ON
OFF
ON
OFF
t_IBH_delay t_IBH12_delay
YES
NON
YES
NON
-5 °C
5 °C
0 °C
30MIN
SCROLL
Heat mode
by heat pump
T4HMAX
T4_AHS_ON
T4<T4_AHS_ON
ON
OFF
t_AHS_delay
ON
ON
OFF
T4
ON
Time
V.2