EAS Electric ETH-80VM Installation & Owner's Manual page 184

Thermal monoblock
Table of Contents

Advertisement

6 MENU
6.1 Operation Mode
See "5.4 OPERARATION MODE" .
6.2 Preset Temperature
PRESET TEMPERATUER has PRESET TEMP\WEATHER
TEMP.SET\ECO MODE 3 items.
6.2.1 PRESET TEMP.
PRESET TEMP.function is used to set different temperature on
different time when the heat mode or cool mode is on.
■ PRESET TEMP.=PRESET TEMPERATUER
■ The PRESET TEMP. function will be off in these conditions.
1) AUTO mode is running.
2) TIMER or WEEKLY SCHEDULE is running.
■ Go to ''MENU'' > ''PRESTE TEMPERATURE'' >
''PRESET TEMP''. Press ''OK''.
The following page will appear:
PRESET TEMPERATURE
PRESET
WEATHER
TEMP.
TEMP.SET
NO.
TIME
1
00:00
2
00:00
3
00:00
SCROLL
PRESET TEMPERATURE
PRESET
TEMP.
NO.
TIME
4
00:00
5
00:00
6
00:00
SCROLL
use ''◄''、''►''、''▼''、''▲'' to scroll and use ''▼''、''▲'' to adjust the
time and the temperature.
When the cursor is on ''■'', as the following page:
PRESET TEMPERATURE
PRESET
TEMP.
NO.
TIME
1
00:00
00:00
2
3
00:00
SELECT
OK
You press ''OK'', and the ''■'' becomes ''
You press ''OK'' again, and the '' '' becomes ''■''. The timer 1 is
unselected.
PRESET TEMPERATURE
PRESET
WEATHER
TEMP.
TEMP.SET
NO.
TIME
TEMPER
1
08:30
2
00:00
3
00:00
ADJUST
SCROLL
ECO
MODE
TEMPER
25°C
25°C
25°C
1/2
WEATHER
ECO
TEMP.SET
MODE
TEMPER
25°C
25°C
25°C
2/2
WEATHER
ECO
TEMP.SET
MODE
TEMPER
25°C
25°C
25°C
SCROLL
1/2
''. The timer 1 is selected.
ECO
MODE
35°C
25°C
25°C
1/2
use ''◄''、''►''、''▼''、''▲'' to scroll and use ''▼''、''▲'' to adjust the
time and the temperature.
Set six periods and six temperatures can be set.
For example: Now time is 8:00 and temperature is 30
PRESET TEMP as follows table.
The following page will appear:
8: 00 08 - 08 - 2015 SAT.
MAIN
27
SET
08:30
NO.
1
2
3
4
5
6
TEMPER
35℃
2 5℃
8 :30 9 :00
INFORMATION
■ when the space operation mode is changed the PRESET TEMP.
is off automatically.
■ The PRESET TEMP. function can be used in the heat mode or
cool mode. But if the operation mode is changed, the PRESET
TEMP. function need reset again.
■ The running preset temperature is invalid when the unit is OFF. It
will run according to the next preset temperature when the unit turn
on again.
6.2.2 WEATHER TEMP.SET
■ WEATHER TEMP.SET=WEATHER TEMPERATURE SET
■ Weather temp.set function is used to preset the desired the water
flow temperature auto maticly depending on the outside air
temperature.During the warmer weather the demand for space
heating is reduced.To prevent the heat pump from producing
excessing water flow temperature for the
weather temp.set can be used to maximise efficiency and reduce
running costs.
Go to ''MENU'' > ''PRESET TEMPERATURE''>''WEATHER TEMP.
SET''. Press''OK''.
The following page will appear:
PRESET TEMPERATURE
PRESET
TEMP.
COOL MODE LOW TEMP.
HEAT MODE LOW TEMP.
ON/OFF
ON/OFF
PRESET TEMPERATURE
PRESET
TEMP.
COOL MODE LOW TEMP.
HEAT MODE LOW TEMP.
ON/OFF
ON/OFF
8
°C. We set the
DHW
ON
ON
55
C
C
TANK
TIME
TEMPER
8:30
35℃
9:00
25℃
10:00
35℃
11:00
25℃
12:00
35℃
13:00
25℃
10 :00 11 :00 12 :00 13 :00
primary circuit, the
WEATHER
ECO
TEMP.SET
MODE
OFF
OFF
SCROLL
WEATHER
ECO
TEMP.SET
MODE
ON
OFF
SCROLL
V.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eth-110vmEth-125vmEth-140vmEth-160vm

Table of Contents