EAS Electric ETH-80VM Installation & Owner's Manual page 158

Thermal monoblock
Table of Contents

Advertisement

Model(s):
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters
shall be declared for low-temperature application.
Parameters shall be declared for average, colder and warmer climate conditions
Item
Rated heat output (*)
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
Tj = bivalent temperature
Tj = operating limit
For air-to-water heat pumps:
Tj = -15℃
Bivalent temperature
Cycling interval capacity for
heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
off mode
standby mode
thermostat-off mode
crankcase heater mode
Other items
Capacity control
Sound power level, indoors/
outdoors
Annual energy consumption
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Annual electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters
YES
NO
NO
NO
NO
NO
Symbol
Value
Unit
Prated
9
kW
Pdh
5.4
kW
Pdh
3.2
kW
Pdh
2.1
kW
Pdh
1.1
kW
Pdh
6.4
kW
Pdh
4.5
kW
Pdh
6.1
kW
-12
°C
T
biv
P
-
kW
cy ch
C
0.9
--
dh
P
0.016
kW
of f
P
0.016
kW
sb
P
0.016
kW
to
P
0.034
kW
ck
variable
L
-/68
dB
WA
kWh
Q
7622
HE
or GJ
-
Q
-
kWh
elec
AEC
-
kWh
EAS ELECTRIC
Pol. Industrial San Carlos, Parcela 13 03370 Redován (Alicante)
www.easelectric.es
ETH-90VM
Item
Seasonal space heating
energy efficiency
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
Tj = bivalent temperature
Tj = operating limit
For air-to-water heat pumps:
Tj = -15℃
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit
temperature
Supplementary heater
Rated heat output (**)
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
Water heating energy
efficiency
Daily fuel consumption
Annual fuel consumption
69
Symbol
Value
ηs
110
COPd
2.32
COPd
3.38
COPd
4.87
COPd
6.25
COPd
1.93
COPd
1.38
COPd
1.79
TOL
-20
COP
or
cy c
-
PERcyc
W
40
TOL
Psup
4.2
-
_
3050
_
-
η
-
wh
Q
-
f uel
AFC
-
Unit
%
-
-
-
-
-
-
-
°C
%
°C
kW
m³/h
3
m
/h
%
kWh
GJ
V.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eth-110vmEth-125vmEth-140vmEth-160vm

Table of Contents