9. 9. Programmable Tone Detector

The tone detector provides center frequency selection with an approximate 7 percent window
of frequency detection granularity around the center frequency. The 4XY token must be used
before the # AB token in order to initiate the programmable detector.
4XY
Selects the frequency for the programmable detector.
# AB
Selects the programmable tone detector (for A and B values, refer to page 52).
XY
00 - 09
Defaults to 100 Hz
10 - 23
1000 Hz - 2300 Hz (100 Hz intervals)
24 - 99
240 Hz - 990 Hz (10 Hz intervals)

9. 9. 1. Example

625 410# 5127
*4 set programmable tone detector frequency
10 look for 1000 Hz frequency
#* enable the programmable tone detector
51 where 5 is the A value (wait for a minimum amount of dial tone) and 1 is the B
value (two seconds)
2
dial destination number
7
through connect

9. 10. 6R1 - Access Number for Carrier Telephone Network

When programmed, this access number will be output on calls routed as a Carrier connection
that requires an access number to be dialled out before allowing access. This Register is dialled
out by using the "3" ACS token. The Default value for all Routes is blank. This entry can be a
maximum of 80 digits.
Register
Where R is the Route Number 1 through 8. This entry may contain up to 80 characters
6R1
maximum, and is Blank by default.
Example: 611 1234567890##
Note: This register should end with a ##, which indicates that the string is finished.
8380-383-115-BA
Issue 1, February 1999
Frequency Selected
Description
Access Control Sequences