R59/R79 - Mf4 Digit Detector Guard Timer; R60/R80 - Mf4 Dialling Rate 2 - Mitel SmarT-1 8380-003-FBCXTX Installation And Programming Manual

Euroroute 1-line dialer
Hide thumbs Also See for SmarT-1 8380-003-FBCXTX:
Table of Contents

Advertisement

Common Option Data

12. 2. R59/R79 - MF4 Digit Detector Guard Timer

You can specify the MF4 guard timer by programming a #1CD token in any 6R5 ACS. This
register sets the minimum length of time that the ACS token #1CD must see an MF4 digit, in
order for the token to determine whether the digit is valid.
Route
Register
Route 1
Route 2
Route 3
Route 4
Route 5
Route 6
Route 7
Route 8
To change all Routes 1 - 4 to the same value use 559 T
To change all Routes 5 - 8 to the same value use 579 T

12. 3. R60/R80 - MF4 Dialling Rate 2

You can specify up to three different MF4 dialling rates in an ACS, using the ACS tokens
1, 2 and 3. Also see Register 102 on page 40, and R61/81 on page 70.
Route
Register
Route 1
Route 2
Route 3
Route 4
Route 5
Route 6
Route 7
Route 8
To change all Routes 1 - 4 to the same value use 560 T
To change all Routes 5 - 8 to the same value use 580 T
69
Default
159 T
0
259 T
0
359 T
0
459 T
0
179 T
0
279 T
0
379 T
0
479 T
0
Default
160 T
6
260 T
6
360 T
6
460 T
6
180 T
6
280 T
6
380 T
6
480 T
6
Description
T = 0 for 40 ms
T = 1 for 40 ms
T = 2 for 50 ms
T = 3 for 60 ms
T = 4 for 70 ms
T = 5 for 80 ms
T = 6 for 90 ms
T = 7 for 100 ms
T = 8 for 110 ms
T = 9 for 120 ms
Description
T = 3 for 70 ms
T = 4 for 80 ms
T = 5 for 90 ms
T = 6 for 100 ms
T = 7 for 110 ms
T = 8 for 120 ms
8380-383-115-BA