9. 9. Programmable Tone Detector

The tone detector provides center frequency selection with an approximate 7 percent window
of frequency detection granularity around the center frequency. The 4XY token must be used
before the # AB token in order to initiate the programmable detector.
4XY
Selects the frequency for the programmable detector.
# AB
Selects the programmable tone detector (for A and B values, refer to page 50).
XY
00 - 09
Defaults to 1000 Hz
1000 Hz - 2300 Hz (100 Hz intervals)
10 - 23
24 - 99
240 Hz - 990 Hz (10 Hz intervals)

9. 9. 1. Example

625 410# 5127
4 set programmable tone detector frequency
10 look for 1000 Hz frequency
#
enable the programmable tone detector
51 where 5 is the A value (wait for a minimum amount of dial tone) and 1 is the B
value (two seconds)
2
dial destination number
7
through connect

9. 10. 6R1 - Access Number for Carrier Telephone Network

When programmed, this access number will be output on calls routed as a Carrier connection
that requires an access number to be dialled out before allowing access. This Register is dialled
out by using the "3" ACS token.
Register
Where R is the Route Number 1 (for Route 0) through 8 (for Route 7). This entry may contain up
6R1
to 80 characters maximum.
Refer to Appendix 2 for country-specific-default data.
Note: This register should end with a ##, which indicates that the string is finished.