Conditions; Procedure; Exiting Data Verification (907); Example For Data Verification Of Register R54 - Mitel SmarT-1 8380-003-FBCXTX Installation And Programming Manual

Euroroute 1-line dialer
Hide thumbs Also See for SmarT-1 8380-003-FBCXTX:
Table of Contents

Advertisement

6. 7. 1. Conditions

The following conditions apply when using Data Verification:
the Dialer must be fully operational.
the PC must be set for 300 bps
you only need to enter 902 once. You will remain in Data Verification provided you do not
exceed the 2 minute programming timer, or manually exit Data Verification.
6. 7. 2. Procedur
To use Data Verification:
1. Enter Programming Mode, the following screen appears:
8380 REV 156A01 COPYRIGHT 1991-1998 MITEL INC. ALL RIGHTS RESERVED.
Serial Number BC00000000
ENTERING PROG. MODE
V>
2. After entering Programming Mode, the Dialer is ready in Data Verification Mode.
3. Enter the desired parameters. When you enter the parameter the data associated with that
parameter appears opposite the entry. If there is no data for the parameter, nothing is
displayed. The Dialer automatically moves to the next entry position. The default value for
register 123 is shown below:
P> 902
V> 123 8

6. 8. Exiting Data Verification (907)

To return to programming mode enter 907. You can re-enter the Data Confirmation mode by
entering 902.
Note: When verifying routes, you cannot enter 5XX, where 5 is the indication that you wish to
verify all the routes. Each Route must be verified individually.

6. 8. 1. Example For Data Verification of Register R54

Enter Programming mode #0
Enter 902
Enter 154 for Route 0
Enter 254 for Route 1
Enter 354 for Route 2
Enter 454 for Route 3
Enter 554, will return a "?"
8380-383-115-BA
Issue 1, February 1999
General Notes on Programming
32