7. System Wide Data
7. 1. General
You can change System Wide Data if the default data does not meet your requirements.
7. 2. 002 - Called Party Programming Enable/Disable
You can specify whether a called party may enter into programming mode after a call is
originated from a line attached to the Dialer.
Register
Default
002 T
Note: If Centrex is enabled and the subscriber dials a local call (does not dial the Centrex
digit(s), they will not be able to enter Called Party Programming, but will remain in a cut
through state.
7. 3. 011 - Carrier Presentation Time for Modem
You can specify the time the internal V.21 300 baud modem will present carrier and try to
establish communication before the Dialer defaults back to MF4 mode programming.
Register
Default
011 T
7. 4. 015 - Rotary Dialling Break Percentage
You can specify the rotary dialling break percentage for either 60 or 66.6 percent.
Register
Default
015 T
8380-383-115-BA
Issue 1, February 1999
CHAPTER 7
T = 0 Disable
1
T = 1 Enable
T = 0 For modem disable
T = 1 For 1 second
T = 2 For 2 seconds
T = 3 For 3 seconds
T = 4 For 4 seconds
T = 5 For 5 seconds
T = 6 For 6 seconds
T = 7 For 7 seconds
T = 8 For 8 seconds
T = 9 For 9 seconds
T =
For 10 seconds
T = 0 For 60% break
0
T = 1 For 66.6% break
System Wide Data
Description
Description
Description
38