103 - On-Hook Time; 105 - Time Between Trunk Release And Next Attempt To Connect; 106 - Flash Generation Timer - Mitel SmarT-1 8380-003-FBCXTX Installation And Programming Manual

Euroroute 1-line dialer
Hide thumbs Also See for SmarT-1 8380-003-FBCXTX:
Table of Contents

Advertisement

Line and Trunk Options

8. 4. 103 - On-hook Time

An on-hook is determined by the absence of loop current on the line from the Exchange, for
the specified amount of time.
Register
103 T

8. 5. 105 - Time Between Trunk Release and Next Attempt to Connect

This option controls the length of time that the Dialer will remain on-hook (in the idle state)
prior to going back off-hook and re-dialling when it performs a drop and reseize.
Register
105 T

8. 6. 106 - Flash Generation Timer

The Flash Generation Timer governs the duration of time that the Access Control Sequence
token 09 will flash the PABX or Centrex line, upon the execution of the token.
Register
106 T
41
Default
T = 0 for 150 ms
T = 1 for 260 ms
T = 2 for 300 ms
2
T = 3 for 340 ms
T = 4 for 380 ms
T = 5 for 420 ms
Default
T = 0 for 5.5 seconds
T = 1 for 6.0 seconds
0
T = 2 for 6.5 seconds
T = 3 for 7.0 seconds
T = 4 for 7.5 seconds
Default
T = 0 for 200 ms
T = 1 for 400 ms
T = 2 for 600 ms
5
T = 3 for 800 ms
T = 4 for 1000 ms
T = 5 for 1200 ms
Description
6 for 460 ms
7 for 500 ms
8 for 700 ms
9 for 1100 ms
for 1300 ms
# for 2500 ms
Description
5 for 8.0 seconds
6 for 8.5 seconds
7 for 9.0 seconds
8 for 9.5 seconds
9 for 10 seconds
Description
6 for 1400 ms
7 for 1600 ms
8 for 1800 ms
9 for 2000 ms
for 2300 ms
# for 2500 ms