13. Firmware Management Utility

13.4 Upgrade Successful

After the upgrade has completed, a screen will appear to inform you that the procedure was successful.
Click Finish to close the Firmware Upgrade Utility.
After a successful completion, the switches will exit Firmware Upgrade Mode and reset.

13.5 Upgrade Failed

If the Upgrade Succeeded screen does not appear, the upgrade failed to complete successfully. Refer to 13.6
Firmware Upgrade Recovery for how to proceed.

13.6 Firmware Upgrade Recovery

There are three conditions that call for firmware upgrade recovery:
• When a firmware upgrade is manually aborted.
• When the mainboard firmware upgrade fails.
• When the I/O firmware upgrade fails.
To perform a firmware upgrade recovery, do the following:
1. Power off the switch.
2. Connect the Firmware Upgrade Cable to its Firmware Upgrade Port.
3. Slide the Firmware Upgrade Recovery Switch to the Recover position.
4. Power the switch back on and repeat the upgrade procedure.
5. After the switch has been successfully upgraded, power it off and slide the Firmware Upgrade Recovery Switch
back to the Normal position.
6. If the switch is one of the cascaded switches, plug it back into the installation.
7. Power the switch back on.