Configurable Flowmeter Module Features and Operational Modes
38

Features Available with the Prover Function

These module features are available with the Totalizer mode prover function.
Module Feature
Prover Direction
Low Frequency Clear
Trigger On
Tie to Counter
Total Overflow
Total Overrange
Total Overspeed
Total Acceleration
Prover Total
Total Counts
Frequency Average
Frequency Period
Speed
Acceleration
Gross Volume
Net Volume
Gross Rate
Net Rate
Prover Direction
You can operate the module as a unidirectional or bidirectional prover. Use
Prover Direction to configure the module for the prover type used in your
application.
Low Frequency Clear
Use Low Frequency Clear to set a minimum frequency level. Any counts
detected below this level will not be used in count calculations.