Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CONVECTION ELEMENT
Refer to page 4-18 for the procedure for servic-
ing the convection element.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the con-
vection element terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
convection element terminals. The meter
should indicate between 14 and 22 Ω
WARNING
Electrical Shock Hazard
CONVECTION FAN MOTOR
Refer to page 4-18 for the procedure for servic-
ing the convection fan motor.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the con-
vection fan motor terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
convection fan motor terminals. The meter
should indicate between 29 and 41 Ω.