Oven Tod; Gas Distribution Valve - KitchenAid KGRA806P Technical Education

Self-cleaning slide-in/freestanding gas ranges
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

OVEN TOD

Refer to page 4-22 for the procedure for ser-
vicing the oven TOD.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the oven
TOD terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
oven TOD terminals. The meter should
indicate a closed circuit (0 Ω).
WARNING
Electrical Shock Hazard

GAS DISTRIBUTION VALVE

Blue
Orange
Red
Refer to page 4-23 for the procedure for ser-
vicing the gas distribution valve.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Remove the storage drawer. NOTE: You
can access the gas distribution valve from
inside the drawer area.
4.
Disconnect the wires from the gas distri-
bution valve terminals.
5.
Set the ohmmeter to the R x 1 scale.
6.
Touch the ohmmeter test leads to the
indicated gas distribution valve terminals.
The meter should indicate as follows:
Terminal 1 (red) to terminal 2 (orange)
= 216 Ω ±30.
Terminal 2 (orange) to terminal 3 (blue)
= 216 Ω ±30.
5-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kgri801pKgsa906pKgsi901p