Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
STANDARD & TRIPLETIER
GAS VALVES
Refer to page 4-4 for the procedure for servic-
ing the standard and TripleTier
To test a gas valve, use a low-pressure ma-
nometer, and measure the inlet and outlet pres-
sure across the valve. There should be no pres-
sure drop. If there is a pressure drop, the valve
should be replaced.
Standard
Gas Valve
Electrical Shock Hazard
gas valves.
TripleTier
Gas Valve
WARNING
DOOR LATCH ASSEMBLY
Motor
Door Switch
Refer to page 4-6 for the procedure for servic-
ing the door latch assembly.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the door
latch assembly component under test.
4.
Set the ohmmeter to the R x 1K scale.
5.
To test the motor, touch the ohmmeter
test leads to the terminals. The meter
should indicate between 2.6K and 3K Ω.
6.
To test the door switch & latch switch:
a) Touch the ohmmeter test leads to the
COM and N.O. terminals. The meter
should indicate an open circuit (infinite).
b) With the ohmmeter test leads con-
nected as stated in the previous step,
press the switch actuator. The meter
should indicate continuity (0 Ω).
5-3
Latch Switch