4.3.4. Power supply - KFM LD control complete and separated

X7 main connection 3-pin
Use mains connection cable that is at least 3 x 1.0 mm
connector (X7) must be pulled out the housing for connection. For connector and terminal diagram, Fig. 6)
Internal device line fuse
F1 and F3 = 5 A mT for the DC link, the electronics are supplied via an additional fuse. The device must be
disconnected from the power supply before checking or changing the fuse! The fuse can only be replaced in
the plant.
When intervening in the device, observe the warning notices on residual Voltage!
Caution
SIEI-AREG GmbH supplies the KFM LD only with the connectors X2, X3, X4 and X7.
All other connectors and cables must be procured or manufactured by the customer.
Important
28
Fig. 18
Item
Wire colour
Connection
1
RD
+24V
2
BK
6
WH
Approval insp.
Tab. 24 Cable for X2
Item
Assignment
1
L1 (230V/50Hz)
2
PE
6
N
Tab. 25 Connection X7
. With KFM LD complete, the 3-pole Phoenix terminal
2
0V
KFM LD • Instruction manual