5.6. Switch setting

5.6.1. Switch and jumper settings during commissioning

The setting of the HEX switch is indicated by a printed arrow. If the set value is changed, the displayed adjust-
ment setting clearly snaps into place. If position "0" is set when setting the switch, LEDs H1 – H4 briefly light
up. This indicator is provided so that adjustments an be made even under poor lighting conditions.
Turn clockwise to increase the setting incrementally until the individual table value is reached.
CAN = 0... Door is not actuated via CAN.
CAN = 1... CAN front side (HS)
CAN = 2... CAN rear side (DL)
In normal operation, only the effect of the parameter setting "Automatic Reopen" (AAU) is overwritten directly
by position 1 – 6 of the HEX switch. This means that the door is also reopened with parameter AAU = 0, e.g.,
in position S1 = S3. The value for "CAN operation", on the other hand, is programmed according to switching
position S1 - position 0– 6 - during automatic commissioning!
This parameter is effective immediately, independent of switching position S1.
S2
Mode
0
Diagnostic unit
1
Slow
2
normal
3
Fast
4
Slow
5
normal
6
Fast
7
Glass door, slow
8
Glass door, normal
9
Glass door, fast
36
S1
Mode
User
0
Diagnostic unit
1
Not possible
2
Not possible
3
Not possible
4
Not possible
5
SIEI-AREG
6
SIEI-AREG USA
Tab. 31 Settings for HEX switch S1
Max. kinet.
Max. speed,
energy
open
7 J
0.3 m/s
10 J
0.45 m/s
20 J
0.65 m/s
7 J
0.3 m/s
10 J
0.45 m/s
20 J
0.6 m/s
5.9 J
0.3 m/s
8.4 J
0.45 m/s
16.8 J
0.65 m/s
Fig. 23
CAN
Automatic reopening
(150 N – characteristic curve)
= 0
Parameter
= 1
0 (inactive)
= 2
0 (inactive)
= 1
1 (active)
= 2
1 (active)
= 0
0 (inactive)
= 0
1 (active)
This is actually only possible!!
Not possible !!
Not possible !!
Max. speed,
Ratio Impulses
close
0.25 m/s
i = 130
0.3 m/s
i = 130
0.4 m/s
i = 130
0.25 m/s
i = 64
0.3 m/s
i = 64
0.35 m/s
i = 64
0.25 m/s
i = 130
0.3 m/s
i = 130
0.4 m/s
i = 130
Default
/cm
Replace F5 and F9
Replace F5 and F9
Replace F5 and F9
Replace F12
Replace F12
Replace F12
Replace F5 and F9
Replace F5 and F9
Replace F5 and F9
KFM LD • Instruction manual