CHAPTER 3: SCOPE
The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this
SECTION 3 .1: To the Installer
system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the
installer's responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards.
In the United States, ANSI Standard 156.10 covers the GT-1175 Slide Door System and ANSI Standard Z97.1 covers Glass
Installation. Other local standards or codes may apply. Use them in addition to the ANSI standard. The GT-1175 is listed with
the Underwriters Laboratory and is identified as such on the label.
Instruct the building owners and operator on the essentials of the operation of the door and this device. The owner should
follow these instructions to determine whether the door is operating properly and should immediately call for service if there
is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians.
The GT-1175 Standard Slide Door system is designed to be installed within a Rough Opening of a Building. The door function
SECTION 3 .2: Objective
is controlled by the U30 Microprocessor Control. This control offers many features to accommodate most installation options.
This manual offers step by step instructions.
A pedestrian Door that does not have Its glass sections installed at the Factory shall specify that
CAUTION
the glazing material employed is to comply with the requirement in UL 325 par .30 .5 .1:
CHAPTER 4: GETTING STARTED
Mechanical Configurations:
SECTION 4 .1: Types of Units
X
Single Slide: (1) Slide Door that slides to the right or left with (1) Sidelite Panel.
X
Bi-Part: (2) Slide Doors that slide apart from the center with (2) Sidelite Panels.
Emergency Egress:
X
Full Open: Both the Slide door and Swing Sidelite break out for emergency egress.
X
Fixed Sidelite: Secured to the Header and Jamb Tube. Only the Slide door breaks out for emergency egress.
Components within the Header are layed out in (1 of 3) different configurations to ensure proper operation of the Drive Belt.
SECTION 4 .2: Header Configuration
However, no matter the configuration, the Power Supply must never be installed between the U30 Microprocessor Control and
the Operator. Please see details listed below:
Operator/Control/Power: Header Width is not wide. Operator needs to be installed to the left of the U30 Control.
X
X
DS150 Operator
DN 0537
"The glazing material in both fixed and sliding panels of all sliding doors and in all
unframed swinging doors shall comply with the requirements in the Performance
Specifications and Methods of Test for Safety Glazing Material Used in Buildings,
ANSI Z97 .1 . Glazing material for other pedestrian doors shall also comply with
ANSI Z97 .1, except that single strength or heavier glass may be used for those
portions of doors involving a glazed area of less than 1ft
dimension greater than 18 in (457 mm)" .
U30 Microprocessor Control
WARNING
To protect against risk of fire 
MOTOR・12P
or electric shock,use only the
certified NABCO power supply.
POWER
M0
Open
61
Gnd
GYRO TECH
Gnd
6B
Open
H
62
CAUTION
BA
ERROR
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
12
There are no user serviceable parts
7
0
inside.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
HEADER
GT1175StandardSlideDoorsInstallationManual;withU30Control
No.
HANDY TERMINAL・6P
Microprocessor Controller
248901-
Mode SW Usage
M1
MODE
Open
TWO WAY
FUNCTION [SLIDING DOOR]
SYMBOL No.
Open
ONE WAY
12VDC+
9DC12V
1
Gnd
HOLD OPEN
12VDC-(Common)
7
2
Gnd
NIGHT
Interior Activation
61
3
Holding Beam
6B
4
Reduced Opening Switch
H
5
M0
6
Mode Switch (see Mode SW Usage shown left)
M1
7
Exterior Activation
62
8
Sequential Activation
SQ
9
Breakout Detector
BA
10
Sidelite Presence Sensor
SLS
11
Contact Output (Class2 Load only)
N/O
OUT.A
12
30V(42.4Vpeak)max.
N/C
OUT.B
13
5Amax.(0-20V), 3.2Amax.(20-30V)
Common
OUT.C
14
Auxiliary Output (Open-Collector)
OUT
15
12VDC-(Common)
7
16
Figure 1 "OCP" with or without Electric Lock
(0 .9 m
) and having no
2
2
Power Supply
P/NC-00105
5 of 56