Keep all incoming 120 VAC wiring separate from low voltage wiring within Header . Do not route
CAUTION
120 VAC wires near the U30 Microprocessor Controller and Motor/Operator .
AC 120V ± 10%
Green (Ground)
White (Neutral)
50 / 60 Hz
Black (Hot )
On/Off
Power Switch
DN 0647
4. Go to the TB1 Port located on the Left side of the Power Supply Module.
5. Insert the Incoming 120 VAC Black (HOT) wire into the Circuit marked "L".
6. Insert the Incoming 120 VAC White (Neutral) wire into the Circuit marked "N".
7. Insert Green (Grounding) wire into the Circuit marked "PE".
8. Ensure the Slide door system is Grounded for safe and consistent operation.
CHAPTER 16: INSTALL WEATHERING
SECTION 16 .1: Door Panels
 16 .1 .1 Fixed Sidelite Units
1. Secure the Brush Holder to the Bottom Rail of Slide door with (3) #6 x 1/2 inch self tap screws.
 16 .1 .2 Full Open Units
1. Secure the Brush Holder to the Bottom Rail of Sidelite Panel with (3) #6 x 1/2 inch self tap screws.
a. It is recommended to leave at least a 1/8 inch gap between the Edge of the Pivot Stile and the Brush Holder, while
allowing 1/8 inch Vinyl to extend past the Brush Holder so the gap is filled.
2. Breakout the Swing Panel.
3. Secure the Brush Holder against the Bottom Rail of Slide door with (3) #6 x 1/2 inch self tapping screws.
Vinyl
Brush
SECTION 16 .2: Door Frame
1. Ensure the entire Door Frame is properly secured to the Rough Opening.
2. Apply caulking bead between the Door Frame and Rough Opening (inside and outside).
3. Apply caulking bead to the Threshold at the bottom of Door Frame.
26 of 56
Power Supply
P/N A-00717
120 VAC
Nominal Dimension*
#6 x 1/2" Self Tapping Screw
WARNING
No.
HANDY TERMINAL・6P
MOTOR・12P
To protect against risk of fire 
or electric shock,use only the
Microprocessor Controller
certified NABCO power supply.
248901-
Mode SW Usage
POWER
M0
M1
MODE
Open
Open
TWO WAY
FUNCTION [SLIDING DOOR]
SYMBOL No.
61
Gnd
Open
ONE WAY
12VDC+
9DC12V
1
GYRO TECH
12VDC-(Common)
6B
Gnd
Gnd
HOLD OPEN
7
2
Open
Gnd
NIGHT
Interior Activation
61
3
Holding Beam
H
6B
4
Reduced Opening Switch
H
5
62
CAUTION
M0
6
Mode Switch (see Mode SW Usage shown left)
M1
7
BA
Exterior Activation
62
8
ERROR
Sequential Activation
SQ
9
Adjustments to the door can only be made
Breakout Detector
BA
10
with the NABCO Handy Terminal.
Sidelite Presence Sensor
SLS
11
Contact Output (Class2 Load only)
N/O
OUT.A
12
Do not disassemble the control box.
30V(42.4Vpeak)max.
There are no user serviceable parts
N/C
OUT.B
13
5Amax.(0-20V), 3.2Amax.(20-30V)
Common
OUT.C
14
inside.
Auxiliary Output (Open-Collector)
OUT
15
To maintain warranty,repairs must be
12VDC-(Common)
7
16
made by authorized NABCO facilities.
U30 Microprocessor Control
P/N V-00020
7/8"*
www.NabcoEntrances.com
12
7
0
Motor/Operator
P/N M-00395
FULL OPEN WITH TRACK
FIXED SIDELITE
Figure 63 Weathering Placement
Rev 5-17-19