Technical Description; Installation Position - Beckhoff AG2400 Operating Instructions Manual

Highend planetary gear unit with output flange
Table of Contents

Advertisement

Technical description

Installation position

7.1
72
───
Observe the maintenance intervals and mounting positions
Carry out maintenance at regular intervals.
In the horizontal mounting position IM V3, liquid which has been left
on the flange for a longer period can penetrate the motor through
capillary action. In mounting position IM V1 liquid can escape.
If you do not observe the maintenance intervals, the motor may
overheat depending on the mounting position. Ingress and leakage
of liquids may damage the motor.
The standard installation position of the gear units is the motor at-
tachment "M". You can use the gear units in any other installation
position.
AG2400
Version: 2.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag2400-tp 010-mf1-5-0c1Ag3400Ag3400-npt 015-mf1-3-1c1

Table of Contents