Maintenance And Cleaning; Cleaning Agents - Beckhoff AG2400 Operating Instructions Manual

Highend planetary gear unit with output flange
Table of Contents

Advertisement

Cleaning agents

10.1
Not applicable
10.1.1
Version: 2.1
WARNING
Shut down and secure the machine or plant
Make sure that the machine or plant is shut down and secured
against accidental start-up.
Failure to observe may result in components moving in the ma-
chine or plant. Rotating or moving components can lead to seri-
ous injuries.
Do not immerse or hose down the gear unit
Wipe the gear unit only with cleaning agent and a cloth.
Due to impermissible solutions, cleaning by immersion can lead to
damage to the surface and the gear unit as well as to leak-tight-
ness problems.
Contamination, dust or chips can have a negative effect on the func-
tion of the components. In the worst case, contamination can lead to
failure. Therefore, clean and service the components at regular in-
tervals.
Clean the components carefully with a damp cloth or a brush.
Use grease-dissolving and non-aggressive cleaning agents such as
isopropanol for cleaning. You will also receive information about
non-approved cleaning agents.
Cleaning agents
Aniline hydrochloride
Bromine
Sodium hypochlorite; bleaching
solution
Mercury (II) chloride
Hydrochloric acid
AG2400

Maintenance and cleaning

Chemical formula
C
H
NH
HCI
6
5
2
Br
2
NaCIO
HgCl
2
HCI
───
83