Specifying the Switcher Controlled by the Control Panel

1
2
3
To select the lighting mode of the switcher bus selection buttons
on the remote panel
When switching buses with the MKS-8080/8082 AUX Bus Remote Panel or
other remote panel connected via S-Bus data link, you can select the lighting
mode of the bus selection buttons.
In the System >System Config >Panel Assign menu, select either of the
following in the <S-Bus Remote Sw'er Status> group.
Mode 1: The inhibited buttons do not light even when pressed, and the other
Mode 2: The delay time for button lighting is reduced, but even the inhibited
18
System Settings (System Config Menu)
In the System >System Config menu, press the [Panel Assign] button.
The Panel Assign menu appears.
Select the switcher to be controlled by the selected control panel, as
follows.
• If there is only one switcher on the network, in the <1st Switcher>
group, set either [SWR1] or [SWR2] to On to select the switcher to be
operated.
In the <2nd Switcher> group, set both [SWR1] and [SWR2] to Off.
• If there are two switchers on the same network, in the <1st Switcher>
group, select the switcher to be operated.
When the system operation mode (see previous item) is set to [Dual
Simul], the switcher status set in <1st Switcher> appears on the control
panel.
To set the selected control panel as tally control master panel, press [Tally
Master], turning it on.
If there are multiple panels and processors, the control panel for which
[Tally Master] is set to On carries out tally control for the whole system.
Notes
When there are multiple control panels, make sure that one of them has
[Tally Master] set to On. When you change the master panel, be sure to
copy and save the setup tally (TLY) and router (RTR) data in the File
menu, and make the same settings for other panels.
If you load the master panel tally data into a panel with a different unit ID,
then [Tally Master] changes to Off.
buttons light after a longer delay time than in Mode 2.
buttons may light for a moment when pressed.