6-3. Accessing Control Panel Menu: DC TIG

2
PPS
AUTO
POST

6-4. Accessing Control Panel Menu: AC And DC Stick

2
DIG
OM-270536 Page 34
.
A complete Parts List is available at www.MillerWelds.com
3
4
150A
OFF
3
4
110A
110A
30%
1
Menu Button
Press Menu button to cycle through paramet-
ers that can be set.
2
Parameter Display
3
Setting Display
4
Encoder
1
Rotate Encoder to adjust parameter setting.
.
Parameter automatically returns to am-
perage setting 15 seconds after Encoder
is inactive.
Amperage Control:
Controls the welding amperage output. Limits the
maximum output of a remote amperage device.
[PPS]* Pulse Control:
Reduces heat input to minimize distortion and in-
crease travel speed. Set PPS (pulses per second).
The range is OFF−250 PPS. The Background Am-
perage and Peak Amperage are not adjustable.
Background Amperage equals 25% of Peak amper-
age. Peak amperage Time equals 40%.
[POST] Post Flow Control:
Controls the length of time gas flows after welding
stops. Range is AUTO, OFF−50T (seconds). AUTO
calculates the time based on the maximum amper-
age of each weld cycle. The minimum time is eight
seconds. Auto = maximum amperage/10.
*PRO−SET: provides PROfessionally developed
SETtings for the welding process. To use PRO−SET,
press the menu button to display the parameter and
adjust the encoder until PRO−SET flashes on the
display. PRO−SET flashes one time and reveals the
professional setting for the parameter.
1
Menu Button
Press Menu button to cycle through paramet-
ers that can be set.
2
Parameter Display
3
Setting Display
4
Encoder
1
Rotate Encoder to adjust parameter setting.
.
Parameter automatically returns to am-
perage setting 15 seconds after Encoder
is inactive.
Amperage Control:
Controls the welding amperage output. Limits the
maximum output of a remote amperage device.
In AC, the user will be setting the rectified average value
of the AC current. [AC AV]will be displayed.
[DIG]* Arc Force Control:
Controls the amount of additional amperage at low
voltage (short arc length) conditions. Adjust the force of
the arc for different joint configurations and electrodes.
Range is OFF−100%. Features PRO−SET values for
6010 and 7018 electrodes.
*PRO−SET
provides
PROfessionally
SETtings for the weld process. To use PRO−SET, press
the menu button to display the parameter and adjust the
encoder until PRO−SET flashes on the display. PRO−
SET flashes one time and reveals the professional set-
ting for the parameter.
*CARB-ARC at one step above DIG's 100%, CARBon
ARC Gouging can be selected.