Foot Controller / Warning Lights - Zepro ZS MK2 Installation Instructions Manual

Tail lift
Hide thumbs Also See for ZS MK2:
Table of Contents

Advertisement

Connection of controller and warning lights
7.2

Foot controller / Warning lights

If the tail lift is equipped with warning lights and/or foot controller, their cabling must be routed and connect-
ed according to the following description.
1. Connect the supplied cable to the connector on the foot controller/warning lights cable.
2. Run the cable and install with cable ties according to Picture 50.
3. Connect the controller cables to ctrl 3 on the relay card. See section 7.3.
4. Connect the warning light cable to WL1 on the relay card. See section 7.3.
IMPORTANT!
Route the cable between the platform and the lift arm tube such that it is well protected when the plat-
form touches the ground.
Leave enough slack to the first cable tie to avoid the risk of damage to the cable during lift operation.
Picture 49. Warning lights and foot controller
36
Picture 50. Installing cabling
ZS MK2