8.5

Calibration

IMPORANT: CALIBRATION MUST BE DONE WITH AT LEAST THE LEFT SYRINGE AND NOZZLE INSTALLED
8.5.1
Bed leveling:
This physically tilts the bed so the distance between needle and bed is the same over the whole print
surface. When to do this?
1.
After unboxing/moving printer.
2. When you see first layer printed lines are deviating from width across the print surface.
8.5.2
Calibrate XYZ
This calibrates the difference between the nozzles. This calibration is only necessary when using 2 syringe
heads in one print. It will align the printheads with respect to each other to get an optimal dual head
print. When to do this?
1.
After exchanging one or 2 syringe(s).
2. When you clearly see that during dual head printing the nozzles are not aligned in x,y direction or
height.