8.3 Load Syringes – Alternative method
An alternative method to move the extruder.
1
2
1.
Press the MOVE button in the main menu
2. Press the Extrude icon in the side bar.
3. Select the left or right extruder.
4. Select the movement distance. Change it to maximally 1ml! A movement of 1mm corresponds to 1.13
e-7 m
is equal to 0.113 ml.
3
5. Depending on where the pusher is wrt to the length to the syringe, the pusher needs to be moved up
or down. The single arrow button gives a slow movement the double arrow gives a fast motion.
Quick Start Guide FELIX BIOprinter