This is the level used to evaluate whether the BERT had an
Error level
"acceptable" bit error rate.
If the BERT has a bit error rate, which exceeds this error level, the
ARGUS will display a "NO" as the test result. 
Using the keypad, you can enter a value ranging from 01 (= 10
(= 10
means that, in the event that the bit error rate is less than 10
error in 10
evaluated as OK.
Setting the HRX value 
HRX value
(Hypothetical Reference Connections, see the ITU-T G.821) 
Using the keypad, you can enter a value ranging from 0 to 100 %.
Setting the MegaBERT bit pattern
Menu
Single Tests
BERT
BERT start
MegaBERT (framed/unfr.)
MegaBERT pattern
The ARGUS will save the setting and start
the single test.
ARGUS PRI
-99
). The default threshold (error level) is 10
6
= 1,000,000 sent bits), the bit error rate test will be
4 Operation on a PRI Access
-06
The various MegaBERT bit patterns that
are available can be called up in "Leased
line" mode as follows:
A distinction is made between two types of
MegaBERT in the channel selection:
- MegaBERT framed (31 B-channels)
- MegaBERT unframed (32 B-channels)
) to 99 
-01
(1E-06). That
-06
(one