4 Operation on a PRI Access
Setting
BERT time
Bit pattern PRI
Error level
HRX value
26
Explanation
You can use the keypad to enter measurement times ranging
from 1 minute to 99 hours and 59 minutes (= 99:59).
If the time is set to 00:00 (=BERT with unlimited
measurement time), the BERT will not stop
automatically. In this case, the BERT must be
terminated manually by pressing the
Default setting: 1 minute
This function is used to select the bit pattern to be sent
cyclically by the ARGUS to perform a BERT on a PRI access
(see "Bit patt. BRI/U"). 
15
(2
-1= default setting).
This is the level used to evaluate whether the BERT had an
"acceptable" bit error rate.
If the BERT has a bit error rate, which exceeds this error level,
the ARGUS will display a "NO" as the test result. 
Using the keypad, this parameter can be set to any value from
-01
01 (= 10
) to 99 (= 10
The default threshold (error level) is 10
that, in the event that the bit error rate is less than 10
6
error in 10
= 1,000,000 sent bits), the bit error rate test will be
evaluated as OK.
Setting the HRX value
(Hypothetical Reference Connections, see the ITU-T G.821)
Using the keypad, you can enter a value ranging from 0 to
100%.
Default setting: 15 %
-99
). 
-06
(1E-06). That means
.
-06
(one
ARGUS PRI