BERT results:
ARGUS PRI
4 Operation on a PRI Access
To scroll through the results
- The evaluation of the results depends on
the error threshold that you set 
(in the example, OK).
- sent data (data transferred)
(K = 1024 bits, k = 1000 bits)
- sync.time in h:min:sec 
(The time in which the ARGUS can sync
to the bit pattern)
- Nb. LOS (counter)
synchronisation is lost at an error rate
greater than or equal to 20 % within a
period of a second. 
The absolute number (Nb.) of
synchronisation losses will be shown.
- LOS time: Duration of the BERT minus
the sync. time 
(The time in which the ARGUS could not
sync to the bit pattern after it had been in
sync at least once)
- abs. err.: The number of bit errors
- rel. err: Bit error rate 
(e.g. 9.7E-07 = 9.7·10
Display of other characteristic values 
(in accordance with ITU-T G.821)
All values are given in percentages and
absolute values. 
The ARGUS evaluates whether the test
results satisfy the limits specified in the
G.821 under consideration of the
reference connection (HRX). 
(The display will show either OK or NO).
To scroll through the results
Return to the previous display
-7
= 0.00000097)