21.2

Recording settings pages

Main window >
example
Allows you to configure the recording settings for all encoders assigned to your system.
The displayed Recording Schedules are configured in Schedules.
Only those columns are described that are not part of a Camera Table.
Recording (only VRM and Local Storage)
Allows you to start or stop recording for this encoder.
Continuous or Prealarm Recording (only VRM and Local Storage)
In the Mode column, select the recording mode:
In the Quality column, click a cell to select the stream quality of stream 1.
If you select Prealarm as the recording mode, click a cell in the Duration [s] column to select
the alarm recording time before the alarm in seconds. The effective recording duration
depends on the maximum target bit rate configured for this encoder. We recommend
configuring at least 15 seconds.
Alarm Recording (only VRM and Local Storage)
In the Stream column, select the stream that is recorded in case of an alarm. The settings in
the next 2 columns are valid for the selected stream. Stream 2 is only selectable for encoders
running ARM firmware.
In the Alarm Quality column, click a cell to select the stream quality of the selected stream.
Only for ARM Firmware: When you select the No modification entry, the same quality is used
for continuous and for alarm recording without any modification. We recommend using the No
modification entry. When you select a stream quality profile, only the values for image
encoding interval and target bit rate are modified according to the settings in this stream
quality profile.
In the Duration [s] column, click a cell to select the alarm recording time in seconds. The
effective recording duration depends on the maximum target bit rate configured for this
encoder. We recommend configuring at least 15 seconds.
To start alarm recording, configure a corresponding alarm or start manual recording in the
Operator Client.
Continuous Recording (only NVR)
In the Quality column, click a cell to disable recording or to select the stream quality of
stream 1.
In the
Live/Pre-event Recording (only NVR)
In the Quality column, click a cell to select the stream quality of the live view (required for
instant playback) and the pre-event recording (required for motion and alarm recording) mode
of stream 2. If dual streaming is active on this encoder, you can select stream 1 to use for live
or pre-event recording.
In the
Bosch Sicherheitssysteme GmbH
Cameras and Recording > Click an icon for recording device, for
> Click a Recording Schedule tab (for example
Click a column title to sort the table by this column.
Continuous: The settings in the next 2 columns are valid for continuous recording.
Prealarm: The settings in the next 2 columns are valid for alarm recording.
column, select a check box to activate audio.
column, select a check box to activate audio.