Elatec TCP3 3.0.3.1 Technical Manual page 50

Hide thumbs Also See for TCP3 3.0.3.1:
Table of Contents

Advertisement

7. Refresh the Firmware on TCP3
5. The Green Power LED will immediately come on and will stay on for the entire upgrade process.
6. After about 40 seconds the Busy LED will blink Red one time then the Status LED will begin blinking
Green. After 8 more seconds the Status LED will stop blinking and the Busy LED will begin blinking
Green.
7. After about a minute and 20 seconds, the Status LED will stop blinking and the Ready LED will begin
blinking Green. 10 seconds later the Ready LED will stop blinking and stay on green.
8. After about a minute and 34 seconds from the start of the upgrade, the Status LED will turn on Red
followed by the Busy LED on green followed by the Ready LED on Orange.
9. At this point the update is complete. This entire process takes about one and one half minutes.
10. The LEDs will continue to turn on in sequence over and over again until power is removed from the
device. No damage will occur if the converter is left in this state for an extended amount of time.
11. Remove power from TCP3
12. Remove the USB flash drive, replace the Elatec card reader and reapply power to the TCP3.
Page 50 of 61