6. Configuration via Web Page
Figure 6.7.: USB Client Setup Screen
Disconnect timeout A Disconnect timeout is provided to service Card readers or Keypads with no pre-
defined "End" character. In this case the converter will close the connection 10 seconds after a character
is received. The timer would reset on each character in the data stream and only 10 seconds after the last
character would it actually close the connection. The converter is default configured to Disconnect 10 sec-
onds after the last character but the user can increase or decrease this time to fit their environment.
The "Apply" button must be selected to save any changes before the user navigates away from this
page.
Page 41 of 61