5. Configuration via TCP3 Config
Figure 5.5.: System Configuration Screen
5.5.0.1. Send Events
Power is applied will send events during the boot process after power has been applied.
Send DHCP Event will notify the Syslog server that the converter received an address from DHCP. It
will include the IP address received. If DHCP is not successful, the converter will assume an address of
192.168.1.1. In this case the converter will not be able to provide any Syslog DHCP status.
Card reader is connected/disconnected will send an event each time the USB card reader is con-
nected or removed.
Configuration Changes will send an event whenever the "Apply" button is selected in any of the config-
uration fields. It will not send details on which changes were made.
5.5.0.2. System Time
The status log will capture events expressed in the default time zone which is Berlin Germany. Use this
setting to change time to your local time zone. Just select the nearest city in your time zone.
5.6. Password Configuration
This section enables the user to change the password on one or many TCP3 units. Once again we need
to be careful updating the password on multiple converters so everything stays in sync. As a result in order
to change the password you must enter it twice. Show Password can also be selected so the password
can be viewed as a final check.
Page 26 of 61
Need help?
Do you have a question about the TCP3 3.0.3.1 and is the answer not in the manual?
Questions and answers