Jmp Instruction - Mitsubishi M16C/60 Series Software Manual

16-bit single-chip microcomputer
Hide thumbs Also See for M16C/60 Series:
Table of Contents

Advertisement

N OTES ON USE
(2) Status flags in decimal mode
When decimal mode is selected (D = 1), the values of three of the flags in the status
register (the flags N, V, and Z) are invalid after a ADC or SBC instruction is executed.
The carry flag (C) is set to "1" if a carry is generated as a result of the calculation, or
is cleared to "0" if a borrow is generated. To determine whether a calculation has
generated a carry, the C flag must be initialized to "0" before each calculation. To check
for a borrow, the C flag must be initialized to "1" before each calculation.
Fig. 4.2.5 Status flags in decimal mode

4.2.4 JMP instruction

When using the JMP instruction in indirect addressing mode, do not specify the last address
on a page as an indirect address.
106
Set D flag to "1"
ADC or SBC instruction
NOP instruction
SEC, CLC, or CLD instruction