Download Print this page

Troubleshooting Chart - Wayne WWB AUTO Operating Instructions And Parts Manual

Advertisement

OPEARATING INSTURCTIONS AND PARTS MANUAL
TROUBLESHOOTING (CONT'D)
5. When temperatures drop below freezing, remove pump from
service and store indoors to protect pump from damage due to
ice. The pump has a unique protection circuit to protect the motor
from a locked impeller condition possibly caused by debris buildup
or from a "frozen" impeller situation caused by ice formation. When
the pump is activated and a locked impeller condition is detected
the unit will automatically shutdown to protect the motor from
overheating. The pump will continue this on/off cycle for a period
of time to attempt to "free" the impeller until eventually the unit
will remain off for a period of 12 hours checking twice a day for a
"freed" impeller. Once the pump is able to operate correctly the
pump will resume normal operation. To reset this delay without
waiting 12 hours momentarily unplug the pump.

TROUBLESHOOTING CHART

Symptom
Possible Cause(s)
Pump will not start
1. Tripped home electrical breaker
or run
2. GFCI tripped
3. Low supply voltage
4. Defective motor
5. Stuck float
6. Impeller obstructed
7. Inlet clogged
8. Pump is sitting uneven
Pump starts and
1. Backflow of water from piping
stops too often
2. Pump is sitting uneven
Pump will not
1. Stuck float
shut off or runs
2. Discharge height exceeds capability
continuously
3. Pump is sitting uneven
Pump operates
1. Impeller obstructed
but delivers little or
no water
2. Obstructed hose
3. Discharge height exceeds capability
4. Inlet clogged
For three year for WWB Auto model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original
purchaser, any part or parts of its Multi-Use Pumps or Water Pumps ("Product") found upon examination by Wayne Water Systems to be defective in materials or
workmanship. Please call Wayne Water Systems (800-237-0987) for warranty instructions. Be prepared to provide the model number and the serial number when
exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance,
or failure to operate in accordance with Wayne Water Systems' written instructions.
THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM
COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE
AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH
THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT
(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along
with the material or correspondence. Please call Wayne Water Systems (800-237-0987) for return authorization and instructions.
DO NOT MAIL THIS FORM TO Wayne Water Systems. Use this form only to maintain your records.
MODEL NO._____________________ SERIAL NO._________________________ INSTALLATION DATE __________________________
ATTACH YOUR RECEIPT HERE
Corrective Action
1. Reset breaker
2. Check for damaged wiring or moisture
3. Contact electrician
4. Replace pump
5. Clean float switch (See Troubleshooting, Figure 2)
6. Remove inlet cover and inlet plate (See Troubleshooting, Figure 1) and check
for debris; clean
7. Follow periodic cleaning steps (See Maintenance, Figure 1)
8. Reposition pump so pump is upright and level
1. Install check valve
2. Reposition pump so pump is upright and level
1. Clean float switch (See Troubleshooting, Figure 2)
2. Reduce discharge height
3. Reposition pump so pump is upright and level
1. Remove inlet cover and inlet plate (See Troubleshooting, Figure 1) and check
for debris; clean
2. Check for kinks, reposition hose or check for debris
3. Reduce discharge height
4. Follow periodic cleaning steps (See Maintenance, Figure 1)
LIMITED WARRANTY
7

Advertisement

loading